Customization: | Available |
---|---|
Application: | Communication |
Type: | Single-mode Fiber |
Still deciding? Get samples of US$ 13.2/km
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Characteristics | Conditions | Specified Values | Units |
Optical Characteristics | |||
Attenuation | 1310nm 1383nm 1550nm 1625nm |
≤0.34 ≤0.31 ≤0.21 ≤0.23 |
dB/km dB/km dB/km dB/km |
Attenuation vs. Wavelength Max. α difference |
1282~1330nm 1525~1575nm |
≤0.03 ≤0.02 |
dB/km dB/km |
Dispersion coefficient | 1285~1340nm 1271~1360nm 1550nm 1625nm |
≤3.5 ≤5.3 ≤18 ≤22 |
ps/(nm·km) ps/(nm·km) ps/(nm·km) ps/(nm·km) |
Zero dispersion wavelength | 1312±12 | nm | |
Zero dispersion slope Typical value |
≤0.091 0.086 |
ps/(nm2·km) ps/(nm2·km) |
|
PMD Maximum Individual Fiber Link Design Value (M=20,Q=0.01%) Typical value |
≤0.2 ≤0.1 0.04 |
ps/km ps/km ps/km |
|
Cable cutoff wavelength | ≤1260 | nm | |
Mode field diameter (MFD) | 1310nm 1550nm |
9.2±0.4 10.4±0.5 |
|
Effective group index of refraction | 1310nm 1550nm |
1.466 1.467 |
|
Point discontinuities | 1310nm 1550nm |
≤0.05 ≤0.05 |
dB dB |
Geometrical Characteristics | |||
Cladding diameter | 124.8±1 | um | |
Cladding non-circularity | ≤1.0 | % | |
Coating diameter | 245±7 | um | |
Coating-cladding concentricity error | ≤12.0 | um | |
Coating non-circularity | ≤6.0 | % | |
Core-cladding concentricity error | ≤0.6 | um | |
Curl (radius) | ≥4 | m | |
Environmental Characteristics | (1310nm, 1550nm & 1625nm) | ||
Temperature dependence Induced attenuation at |
-60ºC to +85ºC |
≤0.05 |
dB/km |
Temperature-humidity cycling Induced attenuation at |
-10ºC to +85ºC, 98% RH |
≤0.05 |
dB/km |
Watersoak dependence Induced attenuation at |
23ºC, for 30 days |
≤0.05 |
dB/km |
Damp heat dependence Induced attenuation at |
85ºC and 85% RH, for 30 days |
≤0.05 |
dB/km |
Dry heat aging at | 85ºC | ≤0.05 | dB/km |
Mechanical Specification | |||
Proof test | Off line | ≥9.0 ≥1.0 ≥100 |
N % kpsi |
Macro-bend induced attenuation 1 turn around a mandrel of 32mm dia. 100 turns around a mandrel of 50 mm dia. 100 turns around a mandrel of 60 mm dia. |
1550nm 1310nm & 1550nm 1625nm |
≤0.05 ≤0.05 ≤0.05 |
dB dB dB |
Coating strip force | Typical average force Peak force |
1.7 ≥1.3 ≤8.9 |
N N |
Dynamic stress corrosion susceptibility parameter (typical) | ≥20 |